CF1400 & CF2300 Burner:
1. Low-high-off operation with two-position air control.
2. Low fire hold switch.
3. Cadmium cell flame detector.
4. 15 second pre-purge/0 second post-purge.
5. 115 Volt/1 Phase/60 Hertz Voltage.
CF2500 and CF3500 Burner:
6. Low-high-off operation with two-position air control.
7. Low fire hold switch.
8. Ultraviolet flame detector.
9. 30 second pre-purge/15 second post-purge.
10. Air flow switch.
11. 230 Volt/1 Phase/ 60Hertz Voltage.
1. Control panel, burner or remote mounted, with on/off switch, control circuit fuse, and terminal strip. Also
available are additional lights, alarm bell and step-down control circuit transformer.
2. Low-high-low burner operation.
3. Air flow switch (CF1400 and CF2300).
4. Various combustion controls. Contact your local Peerless Representative or Peerless Boilers for availability.